ASTM E317-11 PDF

0 Comments

ASTM E Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse- Echo Testing Instruments and Systems without the Use of. ASTM E – Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Testing Instruments and Systems without the Use of. Re: Need ASTM E Urgent please help. Here. Attached Files. File Type: pdf E STD Practice for Evaluating Performance Characteristics of UT.

Author: Gromi Mazuran
Country: Italy
Language: English (Spanish)
Genre: Automotive
Published (Last): 22 January 2004
Pages: 178
PDF File Size: 3.51 Mb
ePub File Size: 15.12 Mb
ISBN: 242-7-66420-772-6
Downloads: 20782
Price: Free* [*Free Regsitration Required]
Uploader: Akinogore

Link to Active This link will always route to the current Active version of the standard. Substitution of these methods is not precluded where appropriate; however, their usage is not within the scope of this practice. Their use, however, should be mutually agreed upon and so identified in the test report. There are limitations to the use of standard reference blocks for that purpose.

Enter your account email address to request a password reset: More comprehensive or precise measurements of the characteristics of complete systems and their components will generally require laboratory techniques and electronic equipment such as oscilloscopes and signal generators. Historical Version s – view previous versions of standard.

If you like to setup a quick demo, let us know at support madcad. Link to Active This link will always route to the current Active version of the standard.

Instrument characteristics measured in accordance with this practice are expressed in terms that relate to their potential usefulness for ultrasonic testing. Significance and Use This practice describes procedures applicable to both shop and field conditions.

In e317–11 case of evaluation of a complete system selection of the specific tests to be made should be done cautiously; if the related parameters are not critical in the intended application, then their inclusion may be unjustified. Remember me aztm one month. This is assumed to be The following editions for this book are also available A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition.

  LUCIANO CANFORA IL MONDO DI ATENE PDF

These procedures can generally be applied to any combination of instrument and search unit of the commonly used types and frequencies, and to most straight-beam examination, either contact or immersed. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Satm moment new editions of the standards you monitor are released, changes are made, or appendixes are published, you will be alerted by email.

E Standard Terminology Relating to Metallography. This document does not establish system acceptance limits, nor is it intended as a comprehensive equipment specification.

ASTM E317:11

More comprehensive or precise measurements of the characteristics of complete systems and their components will generally require laboratory techniques and electronic equipment such as oscilloscopes and signal generators. This ensures that you are always up-to-date and saves you both time and money. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

NOK 1 ,00 excl. This service is not available if you are a URL user where you do not log in with an email address. While these may sometimes be designated gain, attenuator, d317-11 sensitivity on various instruments, the term gain controls will be used in this practice in referring to those which specifically control instrument receiver gain but not including reject, electronic distance-amplitude compensation, or automatic gain control.

ASTM-E, –

This practice is not intended to be used as a substitute for calibration or standardization of an instrument or system to inspect any given material. Certain sections are applicable only to instruments having receiver gain controls calibrated in decibels dB.

Historical Version s – view previous versions of standard Translated Version s: There are limitations to the use of standard reference blocks for that purpose. You need to log in before adding standards to the monitoring service. Print 1 2 3 4 5 page sstarting from page current page.

  KASAR MIE LA GAJI PDF

There were no books found for the applied search filters. FORMAT Single User Subscription Site License Subscription BOOKS All Books PACKAGES All Packages EDITION to PUBLISHER.

Search book title Enter keywords for book title search. Instrument characteristics expressed in purely electronic terms may be measured as described in E Where acceptance criteria are implied herein they are for example only and are subject to more or less restrictive limits imposed by customer’s and end user’s controlling documents.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Enter your personal account email address to request a password reset: While several important characteristics are included, others of possible significance in some applications are not covered.

Certain sections are also compatible with angle-beam, wheel, delay-line, and dual-search unit techniques. No items in cart. Where acceptance criteria are implied herein they are for example only and are subject to more or less restrictive limits imposed by customer’s and end user’s controlling documents.

Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance.

Webprint Printed and bound. This is the prerogative of the using parties and is dependent on application, environment, and stability of equipment. Start Webshop Product catalog Product presentation. Instrument characteristics measured in accordance with this practice are expressed in terms that relate to their potential usefulness for ultrasonic testing.

Land Use and Development.